BLACKOUT MAP

Lantronix · EDS5000

CVE-2025-67038

Lantronix EDS5000, G520, and X300 OS Command Injection

Exploited in attacks Critical 9.3 Attack chance: 20%
Share

What it is

An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The HTTP RPC module executes a shell command to write logs when user's authentication fails. The username is directly concatenated with the command without any sanitization. This allow attackers to inject arbitrary OS commands into the username parameter. Injected commands are executed with root privileges.

CISA: Lantronix EDS5000 contains a code injection vulnerability that could allow attackers to inject arbitrary OS commands into the username parameter. Injected commands are executed with root privileges.

What to do

Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

Deadline for US federal agencies: June 26, 2026

Added to the CISA list
June 23, 2026
Published
March 11, 2026
Severity
Critical 9.3 CVSS 4.0
Chance of attacks in the next 30 days (EPSS)
20% in the top 2.5% of all known vulnerabilities
Weakness
CWE-78 CWE-94
More details
NVD · CVE.org · CISA
All references (3)

Sources: Known Exploited Vulnerabilities (CISA, public domain), CVE records (cve.org) and EPSS (FIRST). The chance of attacks is the EPSS estimate that someone will try to exploit the flaw in the next 30 days.