Internet outage history
Timor-Leste
Operational 18/18 hosts up since Oct 16, 2026 10:00 UTC
Every disruption Blackout Map has recorded in Timor-Leste since monitoring began on October 16, 2026, with reported government shutdowns and submarine cable incidents.
Overview
Last 90 days
Worst status per day, last 90 daysDaily reachability
last 30 daysOur probes · hosts reachable
last 72 hoursIODA · routes and active probing, % of normal
last 72 hoursLatency from our server (Germany)
last 72 hoursThe same measurements as the live panel, per 30 minutes. Times in UTC.
Incidents
All incidents
our probes and IODANo disruptions recorded in Timor-Leste since monitoring started on October 16, 2026.
Attacks and context
Context only — they don't change the status above.
DDoS attacks aimed at Timor-Leste · 7 days
Per hour; each line is relative to its own busiest hour of the week (100%). Context only — attacks never change a country's status.
- Web attacks from
- Viettel Timor Leste 80% · Space Exploration Technologies 10% · Telekomunikasi Indonesia International (T.L.) S.A. 5%
Long-term history
Before our monitoring: IODA archive
94 incidents · 6 blackouts · 43 partial outagesOutages in Timor-Leste detected by IODA (Georgia Tech) between January 2022 and the start of our own monitoring: drops in the country's internet routes (BGP) or in its reachability from IODA's active probing, compared with the day before. Each is checked against IODA's signal; small dips are left out.
| Started (UTC) | Duration | Worst level | Evidence |
|---|---|---|---|
| Sep 5, 2026 08:00 | 50 min | Degraded | IODA (Georgia Tech): routes, lowest 92% of normal |
| Jan 22, 2026 04:45 | 3 hours | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
| Dec 18, 2025 17:15 | 25 min | Degraded | IODA (Georgia Tech): routes, lowest 93% of normal |
| Dec 12, 2025 16:30 | 30 min | Partial outage | IODA (Georgia Tech): active probing, lowest 67% of normal |
| Nov 25, 2025 17:10 | 2 hours | Degraded | IODA (Georgia Tech): routes, lowest 93% of normal |
| Nov 5, 2025 20:30 | 3 hours | Partial outage | IODA (Georgia Tech): active probing, lowest 70% of normal |
| Oct 16, 2025 18:40 | 30 min | Partial outage | IODA (Georgia Tech): active probing, lowest 56% of normal |
| Jul 20, 2025 02:00 | 50 min | Degraded | IODA (Georgia Tech): routes, lowest 95% of normal |
| Jul 4, 2025 12:40 | 40 min | Partial outage | IODA (Georgia Tech): active probing, lowest 70% of normal |
| Jul 2, 2025 09:50 | 30 min | Partial outage | IODA (Georgia Tech): active probing, lowest 72% of normal |
| Jun 20, 2025 19:40 | 40 min | Partial outage | IODA (Georgia Tech): active probing + routes, lowest 73% of normal |
| Mar 28, 2025 16:00 | 5 days | Blackout | IODA (Georgia Tech): routes + active probing, lowest 27% of normal |
Show all 94
| Started (UTC) | Duration | Worst level | Evidence |
|---|---|---|---|
| Mar 25, 2025 22:30 | 2 hours | Degraded | IODA (Georgia Tech): active probing, lowest 86% of normal |
| Mar 25, 2025 20:10 | 1 hour | Degraded | IODA (Georgia Tech): active probing, lowest 80% of normal |
| Mar 13, 2025 22:40 | 50 min | Partial outage | IODA (Georgia Tech): active probing, lowest 68% of normal |
| Mar 4, 2025 16:00 | 14 hours | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
| Feb 2, 2025 11:30 | 2 hours | Partial outage | IODA (Georgia Tech): active probing, lowest 76% of normal |
| Jan 28, 2025 13:35 | 3 hours | Degraded | IODA (Georgia Tech): routes, lowest 83% of normal |
| Dec 27, 2024 15:15 | 9 hours | Degraded | IODA (Georgia Tech): routes + active probing, lowest 94% of normal |
| Dec 12, 2024 16:40 | 30 min | Partial outage | IODA (Georgia Tech): active probing, lowest 69% of normal |
| Oct 28, 2024 23:10 | 30 min | Degraded | IODA (Georgia Tech): active probing, lowest 84% of normal |
| Oct 28, 2024 13:40 | 30 min | Partial outage | IODA (Georgia Tech): active probing, lowest 76% of normal |
| Oct 28, 2024 10:50 | 30 min | Partial outage | IODA (Georgia Tech): active probing, lowest 76% of normal |
| Oct 16, 2024 18:20 | 2 hours | Partial outage | IODA (Georgia Tech): active probing + routes, lowest 68% of normal |
| Oct 12, 2024 09:55 | 1 hour | Degraded | IODA (Georgia Tech): routes, lowest 95% of normal |
| Sep 24, 2024 18:10 | 20 min | Degraded | IODA (Georgia Tech): routes, lowest 95% of normal |
| Aug 29, 2024 20:00 | 2 hours | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
| Aug 27, 2024 17:50 | 2 hours | Partial outage | IODA (Georgia Tech): active probing, lowest 65% of normal |
| Aug 24, 2024 17:40 | 5 hours | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
| Aug 20, 2024 21:25 | 30 min | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
| Aug 19, 2024 17:40 | 5 hours | Degraded | IODA (Georgia Tech): routes, lowest 95% of normal |
| Aug 5, 2024 17:10 | 30 min | Partial outage | IODA (Georgia Tech): active probing, lowest 50% of normal |
| Aug 4, 2024 09:20 | 50 min | Degraded | IODA (Georgia Tech): routes, lowest 95% of normal |
| Aug 4, 2024 02:05 | 40 min | Degraded | IODA (Georgia Tech): routes, lowest 95% of normal |
| Jul 31, 2024 14:15 | 3 hours | Degraded | IODA (Georgia Tech): routes, lowest 95% of normal |
| Jul 16, 2024 16:00 | 12 days | Degraded | IODA (Georgia Tech): routes, lowest 85% of normal |
| Jun 16, 2024 04:10 | 1 hour | Degraded | IODA (Georgia Tech): routes, lowest 95% of normal |
| May 31, 2024 01:00 | 6 days | Partial outage | IODA (Georgia Tech): active probing, lowest 78% of normal |
| May 30, 2024 02:40 | 9 hours | Blackout | IODA (Georgia Tech): active probing, lowest 28% of normal |
| Mar 12, 2024 02:50 | 3 days | Partial outage | IODA (Georgia Tech): routes + active probing, lowest 57% of normal |
| Feb 3, 2024 07:30 | 3 hours | Degraded | IODA (Georgia Tech): routes, lowest 92% of normal |
| Jan 21, 2024 08:30 | 1 hour | Partial outage | IODA (Georgia Tech): active probing, lowest 79% of normal |
| Jan 6, 2024 03:05 | 2 hours | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
| Dec 15, 2023 06:40 | 14 hours | Partial outage | IODA (Georgia Tech): routes + active probing, lowest 75% of normal |
| Dec 4, 2023 05:45 | 2 hours | Degraded | IODA (Georgia Tech): routes, lowest 88% of normal |
| Nov 22, 2023 12:10 | 2 hours | Partial outage | IODA (Georgia Tech): active probing, lowest 52% of normal |
| Nov 19, 2023 12:40 | 3 hours | Blackout | IODA (Georgia Tech): active probing, lowest 16% of normal |
| Oct 14, 2023 17:45 | 2 hours | Partial outage | IODA (Georgia Tech): routes + active probing, lowest 67% of normal |
| Oct 14, 2023 00:40 | 1 hour | Partial outage | IODA (Georgia Tech): active probing + routes, lowest 57% of normal |
| Sep 30, 2023 03:30 | 50 min | Degraded | IODA (Georgia Tech): routes, lowest 93% of normal |
| Sep 16, 2023 05:20 | 2 hours | Degraded | IODA (Georgia Tech): routes, lowest 95% of normal |
| Sep 10, 2023 03:00 | 2 hours | Partial outage | IODA (Georgia Tech): active probing, lowest 74% of normal |
| Sep 6, 2023 21:40 | 30 min | Partial outage | IODA (Georgia Tech): active probing, lowest 68% of normal |
| Sep 1, 2023 12:25 | 50 min | Degraded | IODA (Georgia Tech): routes, lowest 93% of normal |
| Aug 8, 2023 12:50 | 35 hours | Degraded | IODA (Georgia Tech): routes, lowest 95% of normal |
| Aug 5, 2023 05:00 | 30 min | Partial outage | IODA (Georgia Tech): active probing, lowest 78% of normal |
| Jul 21, 2023 11:20 | 1 hour | Partial outage | IODA (Georgia Tech): active probing, lowest 73% of normal |
| Jul 17, 2023 04:40 | 1 hour | Partial outage | IODA (Georgia Tech): active probing + routes, lowest 79% of normal |
| Jun 3, 2023 03:05 | 19 hours | Degraded | IODA (Georgia Tech): routes, lowest 93% of normal |
| Jun 1, 2023 14:50 | 30 min | Partial outage | IODA (Georgia Tech): active probing, lowest 73% of normal |
| May 17, 2023 11:40 | 1 hour | Partial outage | IODA (Georgia Tech): active probing, lowest 55% of normal |
| Apr 2, 2023 21:55 | 7 hours | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
| Mar 20, 2023 03:25 | 5 hours | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
| Mar 13, 2023 16:35 | 11 hours | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
| Feb 26, 2023 03:00 | 6 days | Partial outage | IODA (Georgia Tech): routes + active probing, lowest 67% of normal |
| Feb 23, 2023 05:10 | 30 min | Partial outage | IODA (Georgia Tech): active probing, lowest 75% of normal |
| Feb 22, 2023 16:10 | 6 hours | Partial outage | IODA (Georgia Tech): active probing + routes, lowest 61% of normal |
| Feb 12, 2023 03:10 | 20 hours | Degraded | IODA (Georgia Tech): routes, lowest 93% of normal |
| Jan 28, 2023 03:15 | 2 hours | Degraded | IODA (Georgia Tech): routes, lowest 93% of normal |
| Jan 21, 2023 03:10 | 3 days | Degraded | IODA (Georgia Tech): routes, lowest 93% of normal |
| Dec 18, 2022 03:05 | 4 days | Partial outage | IODA (Georgia Tech): routes + active probing, lowest 58% of normal |
| Nov 28, 2022 04:00 | 8 days | Degraded | IODA (Georgia Tech): routes, lowest 92% of normal |
| Nov 9, 2022 07:10 | 25 hours | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
| Nov 6, 2022 07:05 | 2 hours | Degraded | IODA (Georgia Tech): routes, lowest 93% of normal |
| Oct 22, 2022 03:25 | 3 days | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
| Oct 18, 2022 21:25 | 35 min | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
| Sep 21, 2022 01:40 | 39 hours | Partial outage | IODA (Georgia Tech): routes + active probing, lowest 54% of normal |
| Sep 12, 2022 20:00 | 4 hours | Partial outage | IODA (Georgia Tech): active probing, lowest 61% of normal |
| Sep 1, 2022 08:30 | 50 min | Partial outage | IODA (Georgia Tech): active probing, lowest 58% of normal |
| Jul 27, 2022 07:10 | 50 min | Blackout | IODA (Georgia Tech): active probing, lowest 39% of normal |
| Jul 25, 2022 09:00 | 4 hours | Partial outage | IODA (Georgia Tech): active probing, lowest 64% of normal |
| Jul 18, 2022 15:05 | 2 days | Blackout | IODA (Georgia Tech): routes + active probing, lowest 34% of normal |
| Jul 18, 2022 09:00 | 2 hours | Partial outage | IODA (Georgia Tech): active probing, lowest 58% of normal |
| Jul 17, 2022 20:30 | 2 hours | Degraded | IODA (Georgia Tech): routes, lowest 93% of normal |
| Jun 15, 2022 20:20 | 4 hours | Blackout | IODA (Georgia Tech): active probing, lowest 19% of normal |
| Jun 10, 2022 06:50 | 19 hours | Partial outage | IODA (Georgia Tech): routes + active probing, lowest 61% of normal |
| May 8, 2022 11:30 | 3 hours | Partial outage | IODA (Georgia Tech): active probing, lowest 66% of normal |
| May 8, 2022 04:00 | 40 min | Degraded | IODA (Georgia Tech): active probing, lowest 83% of normal |
| May 8, 2022 00:50 | 50 min | Partial outage | IODA (Georgia Tech): active probing, lowest 69% of normal |
| May 7, 2022 04:50 | 10 hours | Partial outage | IODA (Georgia Tech): active probing, lowest 63% of normal |
| Apr 29, 2022 11:20 | 2 hours | Partial outage | IODA (Georgia Tech): active probing, lowest 67% of normal |
| Apr 18, 2022 02:10 | 30 min | Partial outage | IODA (Georgia Tech): active probing, lowest 67% of normal |
| Mar 25, 2022 09:05 | 5 days | Degraded | IODA (Georgia Tech): routes, lowest 91% of normal |
| Feb 3, 2022 02:35 | 4 days | Degraded | IODA (Georgia Tech): routes, lowest 94% of normal |
Government shutdowns and blocks
since 2019The Internet Society Pulse tracker has no recorded government shutdowns or blocks in Timor-Leste since 2019.
Provided by Internet Society.
Submarine cable incidents
No submarine cable incidents recorded for Timor-Leste.
Cable incidents: GeoCables (CC BY 4.0). Context only — they never change a country's status.