Reolink · RLC-410W IP Camera
CVE-2021-40407
Reolink RLC-410W IP Camera OS Command Injection Vulnerability
Was es ist
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->domain variable, that has the value of the domain parameter provided through the SetDdns API, is not validated properly. This would lead to an OS command injection. An attacker can send an HTTP request to trigger this vulnerability.
CISA: Reolink RLC-410W IP cameras contain an authenticated OS command injection vulnerability in the device network settings functionality.
Was zu tun ist
The impacted product could be end-of-life (EoL) and/or end-of-service (EoS). Users should discontinue product utilization if a current mitigation is unavailable.
Frist für US-Bundesbehörden: 8. Januar 2025
Weitere ausgenutzte Schwachstellen von Reolink
| Hinzugefügt | Schwachstelle | Produkt | Schweregrad | Angriffswahrscheinlichkeit |
|---|---|---|---|---|
| 18.12.2024 | OS Command Injection | Multiple IP Cameras | Hoch 7,2 | 38% |
Quellen: Known Exploited Vulnerabilities (CISA, gemeinfrei), CVE records (cve.org) und EPSS (FIRST). Die Angriffswahrscheinlichkeit ist die EPSS-Schätzung, dass jemand in den nächsten 30 Tagen versucht, die Schwachstelle auszunutzen.